KRD50
series transportation simulation test system is to simulate the actual road
conditions such as shocks and vibrations during the transportation of various
items of a specific load, and to evaluate the effect of the actual working
conditions on the loading, unloading, transportation, packaging, sealing or
internal structure of the goods. In order to assess or confirm the products and
packaging.
l
The method of subband approach is used to simulate broadband random
vibration. Each subband contains a main natural frequency and meets the power
spectrum of the subband. The vibration magnitude and running time of the test
bench are consistent with the actual road spectrum.
l
Adopt truck chassis suspension technology, the acceleration factor
can be adjusted;
l
AC variable frequency control;
l
No special foundation is needed, no other complicated operation or
installation.
Technical
Specifications
|
Model
Parameters
|
KRD
50-200
|
KRD
50-300
|
KRD
50-600
|
KRD
50-1000
|
KRD
50-2000
|
KRD
50-3000
|
KRD
50-4000
|
KRD
50-6000
|
|
Max. Load
(kg)
|
200
|
300
|
600
|
1000
|
2000
|
3000
|
4000
|
6000
|
|
Vibration
Waveform
|
Broadband Random
|
|
Instantaneous Probability
Density Function
|
Approximately
normal distribution
|
|
GRMS of
Acceleration (g)
|
0.32 (0.5-400Hz)
|
|
Simulated Truck
Speed (km/h)
|
20~80
|
|
Simulated
Pavement
|
Intermediate pavement
in tertiary highways & intermediate and low pavement in fourth highways
|
|
Acceleration
Level
|
1:1
|
|
Height of Specimen COG(mm)
|
<500
|
<600
|
<700
|
<800
|
<900
|
<1000
|
<1200
|
<1500
|
|
Working Table Size
(mm)
|
1500×700
|
2000×1200
|
2200×1200
|
2700×1650
|
2700×1800
|
3600×2600
|
4000×2800
|
5000×3500
|
|
Consumption Power (kVA)
|
6
|
10
|
12
|
25
|
30
|
40
|
70
|
90
|
|
Overall Dimension
(mm)
|
1700×850
×1040
|
2000×1550
×1000
|
2200×1500×
950
|
2900×1300×2200
|
2950×2250×1250
|
3600×2600×1450
|
4000×2800×1550
|
5000×3500×1750
|
|
Weight (kg)
|
1150
|
2000
|
3000
|
5500
|
6000
|
8000
|
10000
|
15000
|
|
Power Supply
|
3-phase 380V±10%, 50/60Hz
|
|
Working
Environment
|
Temperature range
0 ~ 40℃, Humidity≤80% (non-condensing)
|
|
Standards
|
GB/T4857.15-89
QJ/T815.1-94
QJ/T815.2-94
GJB150.16-86
|